Kia Sportage: Evaporative Emission Control System / Purge Control Solenoid Valve (PCSV) Description and operation
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls
the passage between the canister and the intake manifold. It is a solenoid valve
and is open when the ECM grounds the valve control line. When the passage is
open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.

Specification
Item
Specification
Coil Resistance (Ω)
22.0 - 26.0 [20°C(68°F)]
...
Circuit Diagram
Terminal Information
Terminal Illustration
Terminal Function
No.
Function
Connected ...
Other information:
Components
ECM directly controls the actuator and VCM flap for link-structure intake manifold
is operated when motor rotates. This creates air tumble. Motor and position
sensor are mounted inside the actuator in order to receive the position of flap
and send feedback to ECM. ...
Specification
Item
Specification
Type
Hall effect sensor
Operating condition (°C)°F
(-40 to 150) -40 to 302
Output voltage (V)
High : 1.18 - 1.68
Low ...